CiteReady is an online personal knowledge management tool. Click to find out more!
 
Updated in 4/9/2020 5:46:53 PM      Viewed: 340 times      (Journal Article)
Journal of anesthesia 20 (3): 243-6 (2006)

Rectal luminal Pr(CO2), measured by automated air tonometry, does not reflect gastric luminal Pr(CO2) in children.

Markus Weiss , Achim Schmitz , Bettina Salgo , Alexander Dullenkopf
ABSTRACT
Rectal luminal regional P(CO2) (Pr(CO2)) was compared with gastric luminal Pr(CO2) measured by automated air tonometry at intervals of 10 min in 20 children aged 6-16 years scheduled for elective surgery under general anesthesia. In 5 patients, measurement of rectal Pr(CO2) failed because of catheter-related problems. In the remaining 15 children, aged 10.6 +/- 2.5 years, 19 +/- 7 paired rectal and gastric Pr(CO2) values (n total, 241) were measured. Bias and precision for gastric compared to rectal Pr(CO2) was -1.79 kPa and 2.89 kPa. In patients with obvious feces in the rectum, bias (precision) for gastric compared to rectal Pr(CO2) was -2.7 kPa (2.6 kPa) and in those with empty rectum, -0.75 kPa (1.42 kPa; t-test; P < 0.001). Based on our in vivo data, rectal luminal Pr(CO2), measured by automated air tonometry, does not reflect gastric luminal Pr(CO2) in children. Enteral luminal gas production within feces in the rectum seems to be a major source of this disagreement.
DOI: 10.1007/s00540-006-0410-0      ISSN: 0913-8668